|
型号
|
图片 |
说明 |
|
|
|
Multiway Multiport Diaphragm Valve, pneumatically operated |
|
|
|
2/2-way valve, pneumatically actuated, stainless steel body, PTFE bellows for fluid separation |
|
|
|
2/2-way Angle-Seat Valve with stainless steel design for media up to +180°C, DN 13-50. Combinable as On/Off System Type 8801-YE |
|
|
|
2/2-way Globe Valve with stainless steel design for media up to +180°C, DN 13-50. Combinable as On/Off System Type 8801-GC |
|
|
|
2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 4-25. Combinable as On/Off System Type 8801-DF or Continuous System Type 8802-DF |
|
|
|
2/2-way Angle-Seat Control Valve with stainless steel design for media up to +180°C, DN 13-50. Combinable as Continuous System Type 8802-YG |
|
|
|
2/2-way Globe Control Valve with stainless steel design for media up to +180°C, DN 13-50. Combinable as Continuous System Type 8802-GD |
|
|
|
Direct-acting 2/2-way Proportional Valve, orifices 0.8 - 2.0 mm |
|
|
|
Direct acting 2/2 way Proportional Valve, orifices 0.8 - 4.0 mm |
|
|
|
Direct-acting 2/2-way Proportional Valve, orifices 2 - 8 mm |
|
|
|
Mini, Small and Compact solenoid valves, 2/2 and 3/2-way, G1/8 - G3/8 and sub-base, brass and stainless steel valve body |
|
|
|
3/2-way Flipper Solenoid Valve, direct acting, 0 - 10 bar, Sub-base, for neutral gases and liquids |
|
|
|
2/2-way solenoid valve, pilot-controlled, for neutral liquids and gases, G1/4 - G3/8, 0-16 bar, switches without differential pressure |
|
|
|
2/2 and 3/2 Way Flipper Solenoid Valve for Analytical Applications, only 4.5 mm wide,medium isulation, for aggressive fluids, direct acting, vacuum up to 7 bar, short response times |
|
|
|
self-priming diaphragm pump for continuous low flow pumping of aggressive pure media; max. 5 ml/min; nearly pulsation free |
|
|
|
self-priming diaphragm pump for precise dispensing of aggressive pure media; bi-directional; max. 5 ml/min; features high repeatability |
|
|
|
Flow sensor for continuous flow measurement, measuring principle: optic or magnetic |
|
|
|
Full Bore Magflowmeter for Low-flow measurement, continuous measurement or Batch Control |
|
|
|
Full Bore Magflowmeter for continuous measurement or batch control - General Purpose |
|
|
|
Full Bore Magflowmeter, Sanitary version, continuous measurement or batch control, mesuring range 0-10 l/h up to 0-280 m3/h |
|
|
|
Gas monitoring system for filling stations. Monitoring the gas recovery at petrol stations. |
|
|
|
Flow sensor for continuous measurement - Ultrasonic using transmit time method, low pressure drop, no flow-settling section necessary in the inlet and/or outlet |
|
|
|
Vibrating level switch with extension tube; universal; for overfill or dry run protection systems; also with ATEX approvals |
|
|
|
General purpose high pressure radar level transmitter, compact for level measurement up to 30m, 4...20 mA/Hart - 2 wires, adjustable with PC, ATEX approvals |
|
|
|
Sanitary and flange radar level transmitter, compact for level measurement up to 20m,4...20 mA/Hart - 2 wires, adjustable with PC, ATEX approvals |
|
|
|
Ultrasonic Level Transmitter, non contact; for fluids and solids; Process connection G 1 1/2 A, NPT 1 1/2" |
|
|
|
Ultrasonic Level Transmitter, non-contact; especially for water and waste water management |
|
|
|
Guided microvave - universal level transmitter; rod or cable version; also with ATEX approval |
|
|
|
pH Sensor, pH measuring system for hygienic process applications |
|
|
|
Conductivity sensor for hygienic process applications, 4-electrode technology for extended measuring range 0.1 µS ... 500 mS |
|
|
|
Modular analysis transmitter for pH, ORP, conductivity measurement |
|
|
|
Control electronics for proportional valves |
|
|
|
Compact Universal controller eCONTROL for flow, pressure or temperature, easy configurable with pneumatically or electrically driven systems |
|
|
|
FreeLINE is a complete automation solution with a higher type of protection IP65/IP67, offering all the freedoms of distributed systems without installation in control cabinet. Electronics and fluidics can be combined particularly easily. |
|
|
|
3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics; 10 mm breadth; orifice DN 4; QNn 300 l/min |
|
|
|
Mass Flow Meter for Gases, "capillary", full scale range 0.01 to 1 lN/min (reference nitrogen) |
|
|
|
Mass Flow Controller for Gases, "capillary", full scale range 0.01 to 1 lN/min (reference nitrogen) |
|
|
|
Magflow transmitter / batch controller, continuous measurement or batch control |